The

XTRAFAST 96 and 120 boiler is a wall mounted modulating

combination boiler with electronic ignition providing central
heating and instantaneous hot water. The boiler is equipped
with a 4 litre domestic hot water storage vessel that ensures
maximum hot water temperature stability during domestic
demand.

The boiler is of the II

2H3+

category for use with Natural Gas (G20)

as distributed in the United Kingdom.

The boiler has a fan assisted balanced flue which both discharges
the products of combustion to and draws the combustion air
from the outside of the room.

The boiler is suitable for top outlet flue connection only.

Both the central heating and domestic hot water temperature
are user adjustable from the boiler control panel.

Domestic hot water demand always has priority over heating
demand.

The boiler is designed for use as part of a sealed water central
heating system with fully pumped circulation. The pump,
expansion vessel and associated safety devices are all fitted
within the boiler.

The boiler can be installed against either an external wall or on
an adjacent inside wall, that is, the flue system will pass directly
to the rear or to either side to the terminal fitted on the outside
wall face.

The installation must be carried out by a competent person in
accordance with the relevant requirements of The Building
Regulations, The Water Byelaws, The Building Standards
(Scotland) Regulations and any applicable local regulations.

These instructions should be carefully followed for the safe and
economical use of your boiler.

Electrical Supply

WARNING: This boiler must be earthed.

All system components shall be of an approved type and shall
be connected in accordance with the current issue of BS7671
and any applicable local regulations.

All external wiring between the appliance and the electrical
supply and earthing requirements shall comply with the current
IEE Regulations.

Connection of the boiler and system controls to the mains
supply must be through a common isolator and must be fused
3A, maximum. This method of connection must be by a fused
double pole isolating switch, with a minimum contact separation

Introduction

of 3mm on both poles. The switch should be readily accessible
and preferably adjacent to the appliance. It should supply the
appliance only and be easily identifiable as so doing.

Alternatively, an unswitched shuttered socket outlet and 3A
fused 3 pin plug, both to the current issue of BS1363 may be
used provided that they are not used in a room containing a bath
or shower.

Wiring to the boiler must be PVC 85

o

C insulated cable, not less

than 0.75mm

2

(24/0.20mm).

Gas safety (Installation and use) Regulations

In your interests and that of gas safety, it is the law that ALL gas
appliances are installed and serviced by a qualified registered
person in accordance with the above regulations.

Gas leak or fault

If a gas leak or fault exists or is suspected, turn the boiler off and
consult the local gas supply company or your installation/
service company.

Air in the heating system

Persistent air in the heating system may indicate leaks in the
system or corrosion taking place. Call your Installation/Servicing
company.

Overheating safety

In the event of a problem, the overheating safety devices cause
safety shutdown of the boiler. If this happens, call your
Installation/Servicing company.

Boiler controls

The control panel, located at the lower front of the boiler casing,
see diagram 1, allows the boiler to be started, shut down,
controlled and monitored during use.

Flue

Do not obstruct the outside terminal of the boiler.

Ancillary equipment

A range of flue accessories are available including vertical
flues, twin-pipe flues, bends etc.

For further information contact your supplier.

1 - On/Off button
2 - Summer/Winter mode selector
3 - Hot water temperature adjuster
4 - Hot water set point display
5 - Graphic display
6 - Heating temperature adjuster
7 - Heating set point display
8 - Display backlight
9 - Clock-timer
(refer to clock-timer
instructions for use).

Diagram 1

9900

Advertising