16 Routine Cleaning and Inspection

SPARK GAP

SENSE GAP

9877

Diagram 16.6

9876

Diagram 16.7

9875

FLOW
RESTRICTOR
AND COLD
WATER INLET
FILTER

16.10 Spark and Sense Gaps

• Check that the spark and sense gaps as shown in diagram
16.6.

16.11 Flue system

• Check externally to make sure that flue is not blocked

• Inspect flue system to make sure that all fittings are secure.

16.12 Operation of fan

• Switch on electrical supply and turn on gas.

• Light burner by opening a hot water tap.

• Check that fan operates when burner lights and stops when it
goes out.

16.13 Cold water inlet filter

Drain down domestic hot water circuit of boiler only, as follows:

• Close isolating valve/throttle (m) on cold water isolating cock,
see diagram 7.1.

Note: This valve is closed when screwed fully clockwise.

• Undo connecting nut from boiler cold water inlet connection.

• Clean and inspect filter, replace if necessary, see diagram
16.7
.

• With both filter and restrictor in place, reconnect connecting
pipe to inlet connection and tighten.

• Fully open isolating valve/throttle on cold water inlet and check
for leaks.