12 optional glass door installation – Golden Blount SF 3624 TV User Manual

Page 12

Advertising
background image

12

OPTIONAL GLASS DOOR INSTALLATION

1. INSTALL GB DOOR TRACKS AND HINGE SPRINGS AS

ILLUSTRATED IN FIGURE 1 USING 6 SCREWS IN KIT.

2. SCREW HANDLES ON TO DOORS.
3. INSTALL DOORS AS SHOWN IN FIGURE 2.

NOTE!

HINGE SPRINGS CAN BE MOVED TO ADJUST DOOR ALIGNMENT.

DOOR LOCKING TABS CAN BE SET BY BENDING UP OR DOWN.

SEE FIGURE 3.

USE MILD SOAP AND WATER TO CLEAN METAL SURFACES.

DO NOT USE BRASS OR ABRASIVE CLEANERS.

ALLOW GLASS TO COOL BEFORE CLEANING.

CAUTION!

BURN WITH DOORS ONLY IN FULL OPEN POSITION.

BROKEN OR DAMAGED COMPONENTS NEED TO BE REMOVED

CAREFULLY. BROKEN GLASS OR HARDWARE CAN BE
REPLACED BY ORIGINAL FACTORY PARTS ONLY. BROKEN
GLASS MUST BE REPLACED BY COMPLETE FACTORY
ASSEMBLED BIFOLD ONLY.

DO NOT SUBSTITUTE ANY MATERIALS NOT MANUFACTURED

SPECIFICALLY FOR THIS APPLIANCE.

DO NOT STRIKE OR SLAM GLASS DOORS WHEN CLOSING.

DO NOT OPERATE THIS APPLIANCE IF GLASS IS BROKEN.

ALLOW GLASS TO COOL BEFORE CLEANING GLASS PANES. GLASS PANES CAN BE

CLEANED WITH A NON-ABRASIVE GLASS CLEANER.

OPERATING GUIDELINES (MILLIVOLT MODEL)

DOOR TRACK
(TOP)

HINGE SPRING

BRIDGE

DOOR TRACK
(BOTTOM)

FIgure #1

FIgure #2

DOOR TRACK
(TOP)

HINGE SPRING

DOOR TRACK
(BOTTOM)

CLIP

FIgure #3

Upon completing the gas line connection,a small
amount of air will be in the lines. When first
lighting the pilot light, it will take a few minutes
for the lines to purge themselves of this air.
Once the purging is complete, the pilot and
burner will light and operate as indicated in the
instruction manual. Subsequent lighting of the
appliance will not require such purging.

CAUTION: DURING THE INITIAL PURGING
AND SUBSEQUENT LIGHTING, NEVER
ALLOW THE GAS VALVE CONTROL KNOB
TO REMAIN DEPRESSED IN THE “PILOT”
POSITION WITHOUT PUSHING THE RED
IGNITOR BUTTON AT LEAST ONCE EVERY
SECOND.

WARNING: CHILDREN AND ADULTS
SHOULD BE ALERTED TO THE HAZARDS
OF HIGH SURFACE TEMPERATURE AND
SHOULD STAY AWAY TO AVOID BURNS OR
CLOTHING IGNITION. YOUNG CHILDREN
SHOULD BE CAREFULLY SUPERVISED
WHEN THEY ARE IN THE SAME ROOM AS
THE APPLIANCE.

IMPORTANT: TURN OFF GAS BEFORE
SERVICING APPLIANCE. IT IS
RECOMMENDED THAT A COMPETENT
SERVICE TECHNICIAN- PERFORM THESE
CHECKUPS AT THE BEGINNING OF EACH
HEATING SEASON.

Advertising