TROUBLE SHOOTING (CONT’D)

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

2. Pilot will not stay lit

A. Defective pilot

1. Check pilot, flame must

after carefully following

generator

impinge on pilot generator.

lighting instructions.

Clean and or adjust pilot for

maximum flame impingement

on generator.

2. Be sure wire connections

from generator at gas valve

terminals are tight and

generator is fully inserted into

pilot bracket.

3. Check thermogenerator

with millivolt meter. Take

reading at “TH-TP” and “TP”

terminals of gas valve.

Should read 325 millivolts

minimum while holding valve

knob depressed in pilot

position, pilot lit, and ON/OFF

switch “OFF”. Replace faulty

generator if reading is below

specified minimum.

B. Defective valve

1. Connect the millivolt

meter probes to the “TH-TP”

and “TP” terminals on the gas

valve. Turn knob to

pilot position, depress and

light pilot light. If meter

reading is greater than 325

m.v. after 30 seconds, the

pilot generator is good. If

pilot does not stay lit, the

valve is defective. If the

meter reading is less than

325 m.v., the thermo-

generator is defective.

C. Open wire connection

1. Check wire continuity and

in pilot circuit

connections in pilot circuit.