TROUBLE SHOOTING (CONT’D)

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

3. Pilot burning, no

A. Damper control lever in

1. Set damper control lever

gas burner, valve knob

closed position

to open position.

“ON”, “ON/OFF” switch

“ON”.

B. “ON/OFF” switch or

1. Check ON/OFF switch

wires defective

and wires for proper connections.

Place jumper wires across

terminals at switch-if burner

comes on, replace defective

switch. If OK, place jumper wires

across switch wires at gas valve-

if burner comes on, wires are

faulty or connections are bad.


C. Thermo generator

1. re-check symptom #2

may not be generat-

ing sufficient milli-

2. Pilot flame not physically close

voltage. (325 m.v.)

enough to thermo-generator.

D. Defective valve

1. Turn valve knob to “ON”,

Place ON/OFF switch to “ON”

Check with millivolt meter at

generator terminals. Millivolt

meter should read greater than

100 m.v. If the reading is OK,

and the burner does not come

on, replace the gas valve.

E. Plugged burner orifice

1. Check burner orifice for

stoppage and remove.

F. Wall switch or wires

1. Follow corrective action in A.1

defective

above; check switch and wiring.

Replace where defective.

4. Pilot and Main Burner

A. High Limit Switch is

1. Allow unit to cool. Then repeat

go out while in operation

defective or has reached

lighting instructions.

its maximum temperature

2. If above does not allow for

ignition, check high limit switch.

Place jumper lines across high

limit switch. If you can re-ignite

the pilot your high limit switch

is defective. Replace high limit

switch before using.

B. No L.P. in tank

1. Check L.P. tank. You may be

of fuel.

C. Bad Thermogenerator

Replace if necessary.