TROUBLE SHOOTING (CONT’D)

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

Pilot will not stay lit

1. Loose wiring on ignitor

wire to ignition module
and/or poor ground to
ignition module

2. Pilot flame too low to sense

3. Flame sensor defective

1. Check wiring connection.

Refer to wiring diagram (see
Wiring Diagram, page 20)

2. Clean and adjust pilot

burner and check gas supply
and inlet pressure to unit

Note: Have a qualified

technician replace pilot
assembly if broken or
corroded

3. Replace flame sensor

Frequent pilot outage

1. Pilot flame may be too low,

causing safety pilot to
“drop out”

2. Improper venting or

excessive blockage

1. Clean and adjust pilot flame

for maximum flame im-
pingement on flame probe

2. Have vent system inspected,

including termination cap.
Remove any restriction or
obstruction

Slight smoke or order during
initial operation

1. Residues from

manufacturing process

1. Problem will stop after a few

hours of operation

Pilot and Main Burner go out
while in operation

1. High Limit Switch is

defective of has reached
its maximum temperature

3. No L.P. in tank

1. Allow unit to cool. Then

repeat lighting instructions.

2. If above does not allow for

ignition, check high limit
switch. Place jumper lines
across high limit switch. If
you can re-ignite the pilot
your high limit switch is
defective. Replace high limit
switch before using

3. Check L.P. tank. You may be

out of fuel