TROUBLE SHOOTING (MILLIVOLT MODEL)

With proper installation and maintenance, your new Gas Fireplace should
provide years of trouble-free service. If you do experience a problem, refer
to the trouble shooting guide shown below. This guide will assist a qualified
service person in the diagnosis of problems and the corrective action to
be taken.

SYMPTOM

POSSIBLE CAUSE

CORRECTIVE ACTION

1. Spark ignitor will not light

A. Defective ignitor (no

1. Check for spark at

pilot after triggering

spark at electrode).

electrode and pilot; if no

spark exist and electrode

wire is properly connected,

replace

ignitor.

B. Defective or misaligned

1. Using a match, light

electrode at pilot (spark

pilot. If pilot lights, turn

at electrode)

off pilot and trigger the

red button again. If pilot

lights, an improper gas/

air mixture caused the

bad lighting and a longer

purge period is recom-

mended. If pilot will not

light - check gap at

electrode

and

pilot

should be 1/8 inch to

have a strong spark. If

OK,

replace

pilot

C. No gas or low gas

1. Check remote shut off

Pressure

valves

from

fireplace.

usually there is a valve

near the fireplace and

sometimes there is a

valve near the main.

there can be more than

one valve between the

fireplace

and

main.

2. Low pressure can be

caused by a variety of

situations such as a

bent line, too narrow

diameter of pipe or even

low

line

pressure.

Check for kinked lines.

If none, consult with

Plumber or gas supplier.

If L.P. Gas is used you

may be out of fuel.

Advertising