16

SETUP

Air/CO

2

Panel

The Air/CO

2

panel is located on the left side of the torso. To access

the panel, lift up the simulator skin flap and remove the protective
covering. Connect external Air/CO

2

.

Air / CO2

Inlet

Air/Co

2

Panel has 2 Connection Ports

Air / CO

2

Inlet

Connecting External Air and CO

2

Supply

An internal compressor is located in the right leg of the Patient
Simulator. It is recommended to use an external source of
compressed air whenever the Patient Simulator is stationary over
extended periods of use.

Connect CO

2

only if the Patient Simulator is required to exhale

CO

2

with each ventilation. Exhaled CO

2

can be detected with a real

capnographic device. The Patient Simulator will only exhale CO

2

when a capnograph is registered as being connected to the system.

1 Connect a suitable CO

2

source to a Laerdal external

compressor or regulator panel.

2 Connect a Laerdal double-lumen Air/CO

2

tube from the

external compressor or regulator panel to the Air/CO

2

inlet on

the panel.

Note: For more information on external compressors and
regulator panels compatible with SimMan Essential, contact your
local Laerdal representative.

The IV Arm

Follow these instructions when using the IV Arm for SimMan
Essential.

The Patient Simulator must be switched ON when performing the
following.

IV Arm with Skin

Filling and Priming port

Priming switch

IV Arm Pad

Drain tube

IV Arm without Skin

Filling and Priming port

Priming switch
Tourniquet area

IV Arm chassis

Drain tube

The IV Arm Pad

The IV Arm Pads have been tested and
proven capable of multiple IV catheter
insertions/retractions.

To maximize the life of the IV pad we
suggest that you insert the IV catheter in
the region highlighted on pad.