Airway features, Features, Other applications – Laerdal SimMan Essential User Manual

Page 8: Simdesigner, Web downloads, Configurable airway features

Advertising
background image

8

FEATURES

Other Applications

There are also other programs that are used in conjunction with
the simulation sessions, for example License Manager for handling
program licenses and Simulator Firmware & Network Fixer for
updating the firmware of the simulators or troubleshooting network
problems.

SimDesigner

The SimDesigner application allows you to configure your own
preprogrammed scenarios. It can also be used to analyze and print
out a graphical representation of a scenario.

SimDesigner must be installed to allow conversion of legacy
instructor application files to LLEAP compatible file formats.

For a full overview of all applications and their help files, start LLEAP
Home.

Web Downloads

Visit www.laerdal.com/download to download the latest User Guide
and Software.

Airway Features

The airway is anatomically modeled as far as the bronchia.

The airways can be manipulated by a learner:

− Head tilt/Chin lift

− Jaw thrust w/articulated jaw

− Cricoid pressure and manipulation

− Suctioning (oral & nasopharyngeal)

If the tongue fallback feature is enabled, head tilt is required to open
the airways for mask ventilations.

The Patient Simulator may be ventilated by normal and

emergency methods:

− Bag-mask ventilation

− Orotracheal intubation

− Nasotracheal intubation

− Transtracheal intubation

Prior to using airway adjuncts, apply a small amount of Laerdal
Airway Lubricant to the equipment. Do not spray lubricant directly
into the airway,

The following equipment or methods are suitable to secure

the Patient Simulator’s airway:

− Laryngeal mask airways: The airways are designed for use with

size #4, but size #5 may also seal correctly.

− Endotracheal tube intubation, Size ID 7.5 - 8.5 is suitable, but

using the smaller size reduces wear of the Patient Simulator’s
airways.

Use of a malleable stylet is recommended - make sure it does not
extend beyond the ET tube.

Recommended styles:

− i-Gel

− Fiberoptic intubation

− Combitube (size small adult is suitable)

− Retrograde intubation

− Needle cricothyrotomy

− Surgical cricothyrotomy

The following Patient Simulator features indicate incorrect

tube placement:

− Right main stem intubation – unilateral chest rise

− Stomach distention

− Lack of chest sounds, CO

2

exhalation (see Breathing Features

section)

Configurable Airway Features

Patient Simulator features may be configured to present various
airway scenarios:

− There are two settings of airway resistance: On/Off

− Tongue edema - multiple levels

− Pharyngeal swelling

− Laryngospasm

− Decreased cervical range of motion

− Trismus

− Teeth - soft upper dentures may be replaced with a hard set of

teeth for enhanced realism while practicing intubations.

During simulation, the following conditions can be set:

− Can’t intubate/can ventilate

− Can’t intubate/can’t ventilate

The following information is automatically registered in the

SimMan Essential simulation session:

− Detection of proper head position.

− Jaw Thrust

− Pneumothorax decompression

− Ventilations

− Stomach distension

Note: In LLEAP the airway and breathing status for the current
simulator is shown in a window. Settings for lung resistance can be
made. See LLEAP Help for further information.