Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from go-

ing into pipe. Excess sealant in pipe could result

in clogged fireplace valves. Never use sealant on

flare threads.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install a sediment trap in

supply line as shown in Figure 15. Locate sediment

trap where it is within reach for cleaning. Install in

piping system between fuel supply and fireplace.

Locate sediment trap where trapped matter is not

likely to freeze. A sediment trap traps moisture and

contaminants. This keeps them from going into fire-

place gas controls. If sediment trap is not installed or

is installed wrong, fireplace may not run properly.

INSTALLATION

Continued

Figure 15 - Gas Connection

* Purchase the optional CSA design-certified

equipment shutoff valve from your dealer. See

Accessories, page 36.

Natural
From Gas
Meter
(5" W.C. to
10.5" W.C.
Pressure)

Propane/LP
From
External
Regulator
(11" W.C.
to 14" W.C.
Pressure

CSA Design-Certified
Equipment Shutoff
Valve With 1/8" NPT
Tap*

3" Minimum

Sediment Trap

Pipe

Cap

Tee

Nipple

Joint

CONNECTING FIREPLACE TO GAS
SUPPLY

Installation Items Needed

• 5/16" hex socket wrench or nut-driver

• Phillips screwdriver

• sealant (resistant to propane/LP gas, not provided)

1. If fireplace screen and floor are still installed,

see Removing Fireplace Screen and Floor

Assembly, page 9.

2. Route gas line (provided by installer) from

equipment shutoff valve to fireplace. Route

flexible gas supply line through one of the

access holes.

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 16).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

3. Attach the flexible gas line to gas supply (see

Figure 16). Check tightness of flexible gas

line attached to gas regulator of fireplace (see

Figure 16).

4. Check all gas connections for leaks. See

Checking Gas Connections, page 15.

5. Replace fireplace floor assembly. Feed flexible

gas line into fireplace base area while replacing

fireplace floor assembly. Make sure the entire

flexible gas line is in fireplace base area.

Note: Be careful of wires and components on

underside of fireplace floor. Reattach fireplace

floor assembly with screws removed in step

3 of Removing Fireplace Screen and Floor

Assembly, page 9.

Figure 16 - Attaching Gas Lines Together

From Gas Meter (Natural)
From External Regulator
(Propane/LP)

To Fireplace Gas
Regulator

Equipment
Shutoff Valve
Provided by
Installer

Flexible Gas Line from
Fireplace Gas Regulator

Advertising