11. Place metal trim on shoulder screws located

on the side and top of the fireplace (see As-

sembling and Attaching Optional Perimeter

Trim, page 19). Firmly snap trim over shoulder

screws. Align fireplace in mantel assembly so

the trim overlaps mantel evenly on all three

sides.

12. Lower bottom louver door. Use 3" wood screws

provided with mantel accessory to attach fire-

place to base (see mantel instruction sheet).

INSTALLATION

Continued

Figure 23 - Inserting Fireplace Into

Cabinet Mantel

Figure 22 - Location of Nailing Flanges

Nailing
Flanges

BUILT-IN FIREPLACE
INSTALLATION

Built-in installation of this fireplace involves install-

ing fireplace into a framed-in enclosure. This makes

the front of fireplace flush with wall. If installing

a mantel above the fireplace, you must follow the

clearances shown in Figure 27, page 18. Follow

the instructions below to install the fireplace in

this manner.

Actual

Framing

Height

3

3

/

8

"

33"

Front Width

34

5

/

16

"

35

1

/



"

Depth

16

11

/

16

"

17

3

/

4

"

1. Frame in rough opening. Use dimensions shown

in Figure 24 for the rough opening. If installing

in a corner, use dimensions shown in Figure 25

for the rough opening. The height is 33" which

is the same as the wall opening above.

2. Install and properly ground GA3555, three-

prong 120 volt electrical outlet, in fireplace.

Follow instructions included in kit (see Ac-

cessories, page 36).

3. If not already completed, install gas piping to

fireplace location. This installation includes an

approved flexible gas line (if allowed by local

codes) after the equipment shutoff valve. The

flexible gas line must be the last item installed

on the gas piping. See Installing Gas Piping

to Fireplace Location, page 13.

4. Carefully set fireplace in front of rough opening

with back of fireplace inside wall opening.

5. Attach flexible gas line to gas supply. See Con-

necting Fireplace to Gas Supply, page 14.

6. Plug electrical cord(s) into electrical outlet

installed in step 2.

7. Carefully insert fireplace into rough opening.

8. Attach fireplace to wall studs using nails or

wood screws through holes in nailing flange

(see Figure 26, page 18).

9. Check all gas connections for leaks. See

Checking Gas Connections, pages 15.

10. Install trim. See Assembling and Attaching

Optional Perimeter Trim, page 19.

35

1

/

2

"

17

3

/

4

"

33"

39

3

/

8

"

27

7

/

8

"

55

5

/

8

"

35

1

/

2

"

Figure 24 - Rough Opening for Installing

in Wall

Figure 25 - Rough Opening for Installing

in Corner