Operating fireplace – Desa VTGF33NRB User Manual

Page 22

Advertising
background image

www.desatech.com

113134-01F



NORMAL LIGHTING

INSTRUCTIONS

WARNING: You must oper-

ate this heater with the fireplace

screen in place. Make sure fire-

place screen is in place before

running heater.

NOTICE: During initial operation

of new heater, burning logs will

give off a paper-burning smell.

Open damper or window to vent

smell. This will only last a few

hours.

1. STOP! Read the safety information, page 21.

2. Make sure equipment shutoff valve is

fully open.

3. Wait five (5) minutes to clear out any gas.

Smell for gas around heater and near floor.

If you smell gas, STOP! Follow “B” in the

safety information on warnings plate. If you

don’t smell gas, go to the next step.

A. Using Supplied Wall Switch Assembly

1. Set manual ignition bypass switch on the

control panel to the OFF position (auto-

matic ignition position).

2. Press ON/OFF button. Hold for 6 seconds.

Gas valve will open and electronic ignition

will begin sparking to light pilot. LED will

light. Note: You may be running this heater

for the first time after connecting to gas sup-

ply or at the start of your heating season.

If so, the ON/OFF button may need to be

pressed again. This will allow air to bleed

from gas system. If several attempts to light

pilot fail, contact a qualified service person

or gas supplier for repairs. Until repairs

are made, light and operate manually (see

Manual Lighting Instructions for Electric

Power Outage, page 19).

3. When pilot flame is lit, the thermocouple is

heated by the flame. When thermocouple

becomes hot (5 to 15 seconds), main burner

will automatically light on high flame.

4. To lower flame, push HI/LO button on wall

switch once. Note: This fireplace does not

have a pilot-only mode.

OPERATING FIREPLACE

Continued

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Automatic Ignitor
Electrode

Pilot
Burner

Figure 38 - Pilot (Propane/LP Gas

Shown)

Manual Ignitor
Electrode

Manual Ignition Bypass Switch
(Up is for Remote Control)

ON/OFF Button

HI/LO Button

Wall Switch
Assembly

Figure 37 - Control Locations

LED

Thermocouple

B. Using Hand-Held Wireless Remote
Control

1. Set manual ignition bypass switch on

control panel to OFF position (automatic

ignition position).

2. Wait five (5) minutes to clear out any gas.

Smell for gas around heater and near floor.

If you smell gas, STOP! Follow “B” in the

safety information on warnings plate. If you

don’t smell gas, go to the next step.

3. Point remote control toward the lower

front of fireplace and push both buttons

at the same time. Hold for 6 seconds. The

gas valve will open and electronic ignition

will begin sparking to light the pilot. Note:

You will be able to hear a clicking sound

during this process. LED on wall switch

will light.