PRESSURE TESTING FIREPLACE GAS
CONNECTIONS

1. Open equipment shutoff valve (see Figure 17,

page 15).

2. Open main gas valve located on or near gas

meter for natural gas or open propane/LP

supply tank valve.

3. Place manual ignition switch in the OFF

position.

4. Check all joints from equipment shutoff valve

to gas valve (see Figure 18 or 19, page 15).

Apply noncorrosive leak detection fluid to all

joints. Bubbles forming show a leak.

5. Correct all leaks at once.

6. Light fireplace (see Operating Fireplace, page

21). Check all other internal joints for leaks.

7. Turn off fireplace (see To Turn Off Gas to

Appliance, pages 23 or 24).

CONVENTIONAL FIREPLACE
INSTALLATION

Conventional installation of fireplace involves in-

stalling fireplace along with corner, face or cabinet

mantel with hearth base accessories against a wall

in your home.
Note:

Refer to instructions provided with the man-

tel for assembly instructions. Refer to the follow-

ing instructions for system installation. Refer to

instructions on page 23 for hood assembly. Blower

accessory should be installed prior to mantel if it is

being used (see Installing Variable Speed Blower

Accessory, page 13, or Installing Thermostatic

Blower Accessory, page 15).

1. Assemble cabinet mantel as shown in acces-

sory instruction sheet.

2. If blower is installed, install a properly

grounded, 120 volt three-prong electrical out-

let at fireplace location if an outlet is not there.

If possible, locate outlet so cabinet mantel will

cover it when installed (see Figure 20).

3. Place hearth base against wall at installation

location. Cut an access hole in hearth base to

run gas line to fireplace (see Figure 20). Make

sure to locate access hole so cabinet mantel will

cover it when installed. Note: You can secure

base to floor using wood screws. Countersink

screw heads and putty over.

4. Route flexible gas line through access hole in

hearth base.

INSTALLATION

Continued

5. Center cabinet mantel on hearth base (see Figure

21). Make sure mantel is flush against wall and

centered left to right on base.

6. Use screws provided with mantel accessory

to attach mantel assembly to base (see mantel

instruction sheet).

7. Attach flexible gas line to fireplace gas regula-

tor. See Connecting Fireplace to Gas Supply,

page 14.

8. Route electrical cord(s) through access holes

in either side of fireplace with bushing. Plug

electrical cord(s) into electrical outlet.

9. Check all gas connections for leaks. See

Checking Gas Connections, page 15.

10. Break off nailing flanges (see Figure 22, page

17) with hammer or pliers if applicable and

place fireplace inside mantel opening. See

mantel instruction sheet for specific installa-

tion instructions. Be careful not to scratch or

damage hearth base or cabinet mantel.

Figure 20 - Placing Hearth Base

Accessory Against Wall

Electrical
Outlet

Hearth Base

Rigid Pipe
and Gas
Shutoff Valve

Gas Line
Access
Hole

Figure 21 - Installing Cabinet Mantel

Cabinet