Operating fireplace – Desa VTGF33NRB User Manual

Page 23

Advertising
background image

www.desatech.com

113134-01F

3

Note: You may be running this heater for

the first time after connecting to gas supply

or at the start of your heating season. If so,

the ON button may need to be pressed again.

This will allow air to bleed from gas system.

If several attempts to light pilot fail, contact

a qualified service person or gas supplier

for repairs. Until repairs are made, light

and operate manually (see Manual Lighting

Instructions for Electrical Power Outage).

4. When pilot flame is lit, the thermocouple is

heated by the flame. When thermocouple

becomes hot (5 to 15 seconds), main burner

will automatically light on high flame.

5. To lower flame, point remote control

toward lower front of fireplace and push

HI/LO button once.

Note: This fireplace does not have a pilot-

only mode.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater - Wall Switch

Push ON/OFF button on wall switch once.
Shutting Off Heater - Wireless Remote
Control

Point remote control toward lower front of fire-

place and push both buttons at the same time.

MANUAL LIGHTING

INSTRUCTIONS FOR

ELECTRICAL

POWER OUTAGE

WARNING: You must oper-

ate this heater with the fireplace

screen in place. Make sure fire-

place screen is in place before

running heater.

NOTICE: During initial operation

of new heater, burning logs will

give off a paper-burning smell.

Open damper or window to vent

smell. This will only last a few

hours.

OPERATING FIREPLACE

Continued

HI/LO
Button

Piezo Ignitor

Wall
Switch

LED

Figure 39 - Control Locations

Manual Ignition
Bypass Switch
(Down is ON)

ON/OFF
Button

Magnetic Manual
Override Handle

Gas Valve

Because this fireplace has an electronic ignition

system, in the event there is a loss of power, it

will be necessary to manually light the pilot with

the piezo ignitor. After the pilot is lit, the main

burner will light automatically.

1. Follow steps 1 through 3 under Normal

Lighting Instructions, page 22.

2. Set manual ignition bypass switch on con-

trol panel to ON position (manual ignition

position). See Figure 39.

3. The pilot is attached to the rear of the front

burner. You will be able to see the pilot

and spark electrode without removing the

screen or logs.

4. Place the magnetic manual override handle,

provided with this unit, on the end of the

gas valve stem (see Figure 39).

5. Turn the override handle fully counterclock-

wise

to the PILOT position. The handle

will not stop but will begin to slip when you

have fully turned to the PILOT position.

6. While holding the valve handle in the

PILOT position, press and release piezo

ignitor button (see Figure 39). This will light

the pilot. If needed, keep pressing ignitor

button until pilot lights.

7. When pilot flame is lit, hold manual over-

ride handle until thermocouple heats (ap-

proximately 5 to 15 seconds). If pilot goes

out, repeat process. If several attempts

to light the pilot fail, contact a qualified

service person or gas supplier for repairs.

8. When thermocouple is heated, release

override handle. The main burner will im-

mediately light on high flame. Adjust flame

size by turning override handle.

Advertising