C-BOX 100 Pinout for DX6400:


The table below gives the pinout of the C-BOX 100 terminal block connectors. Use this pinout when the DX6400
reader is connected in a network by means of the C-BOX 100:

C-BOX 100 Terminal Block Connectors

Power

1, 3, 5

VS

2, 4, 6

GND

7, 8

EARTH GROUND

20, 40

Reserved

Inputs

27

EXT TRIG/PS A (polarity insensitive) for PS

28

EXT TRIG/PS B (polarity insensitive) for PS

29

IN 2/ENC A (polarity insensitive) for Encoder

30

IN 2/ENC B (polarity insensitive) for Encoder

31, 33

IN 3A (polarity insensitive)

32, 34

IN 4A (polarity insensitive)

36

IN 3B/IN 4B Reference (polarity insensitive)

Outputs

21 OUT

1+

22 OUT

1-

23 OUT

2+

24 OUT

2-

25

OUT 3A (polarity insensitive)

26

OUT 3B (polarity insensitive)

Auxiliary Interface

35 TX

AUX

37 RX

AUX

38, 39

GND

Main Interface

RS232

RS485

Full-Duplex

RS485

Half-Duplex

20 mA C.L.

(with INT-30 only)

11, 15

TX232

TX485+

RTX485+

12, 16

RTS232

TX485-

RTX485-

17 RX232

*

RX485+

18 CTS232

*

RX485-

10, 14, 19

SGND Main Isolated

SGND Main Isolated

SGND Main Isolated

9, 13

RS485 Cable Shield

RS485 Cable Shield

see INT-30

instructions


* Do not leave floating, see Reference Manual for connection details.