COMMON FEATURES

20

User Interface:

RS232 PC-side connections

1

5

9

6

9-pin male connector

13

25

14

1

25-pin male connector

Pin Name

Pin

Name

2 RX

3

RX

3 TX

2

TX

5 GND

7

GND

7 RTS

4

RTS

8 CTS

5

CTS


How To Build A Simple Interface Test Cable:


The following wiring diagram shows a simple test cable including power, external (push-button) trigger and PC
RS232 COM port connections.

25-pin D-sub female

23

20

GND

RXAUX

TXAUX

21

DX6400

25

13

GND

VS

9-pin D-sub female

GND

TX

RX

PC

2

3

5

18

9

EXT TRIG A

VS

Power Supply

VS (15 – 30 VDC)
Power GND

Trigger

EXT TRIG B