Network termination – Datalogic Scanning DX6400 User Manual

Page 6

Advertising
background image

DX6400 MASTER/SLAVE MODEL

4

The details of the connector pins are indicated in the following table:

25-pin D-Sub Connector Pinout

Pin Name

Function
Chassis - internally connected to GND

1 CHASSIS

Cable shield connected to chassis

20

RXAUX

Receive data of auxiliary RS232 (referred to GND)

21

TXAUX

Transmit data of auxiliary RS232 (referred to GND)

8

OUT 1+

Configurable digital output 1 – positive pin

22

OUT 1-

Configurable digital output 1 – negative pin

11 OUT

2+

Configurable

digital output 2 – positive pin

12

OUT 2-

Configurable digital output 2 – negative pin

16 OUT

3A

Configurable

digital

output 3 – polarity insensitive

17 OUT

3B

Configurable

digital

output 3 – polarity insensitive

18

EXT_TRIG/PS A External trigger (polarity insensitive) for PS

19

EXT_TRIG/PS B External trigger (polarity insensitive) for PS

6

IN2/ENC A

Input signal 2 (polarity insensitive) for Encoder

10

IN2/ENC B

Input signal 2 (polarity insensitive) for Encoder

14

IN3A

Input signal 3 (polarity insensitive)

15

IN4A

Input signal 4 (polarity insensitive)

24

IN_REF

Common reference of IN3 and IN4 (polarity insensitive)

9, 13 VS

Supply voltage – positive pin

23, 25 GND

Supply voltage – negative pin

14

1

25

13

25-pin male D-sub Connector

Pin

RS232

RS485 Full-Duplex

RS485 Half-Duplex

20 mA C.L.

(INT-30 with C-BOX 100 only)

2 TX

TX485+ RTX485+

3 RX

*

RX485+

4 RTS

TX485-

RTX485-

5 CTS

*

RX485-

7 GND_ISO

GND_ISO GND_ISO

see INT-30 instructions

* Do not leave floating, see Reference Manual for connection details.

9-pin Lonworks Connector Pinout

Pin Name

Function
Cable shield internally connected

1 CHASSIS

by capacitor to chassis

9

VS

Supply voltage – positive pin

2

GND

Supply voltage – negative pin

6

VS_I/O

Supply voltage of I/O circuit

3 Ref_I/O

Reference voltage of I/O circuit

4 SYS_ENC_I/O

System

signal

5 SYS_I/O

System

signal

7

LON A

Lonworks line (polarity insensitive)

8

LON B

Lonworks line (polarity insensitive)

5

1

9

6

Female

1

5

6

9

Male

9-pin Local Lonworks Connectors


Network Termination:


When building a local Lonworks system the network must be properly terminated by positioning a BTK-6000
terminator on the DX6400 master reader (BTK-6000 female side) and on the last slave reader (BTK-6000 male
side).

BTK-6000 Network Terminator

to Master

9-pin female

to Slave

9-pin male

Advertising