Column Heading

Description

Rate Match FIFO Used

Enter whether or not the rate matching FIFO is

used.
To enter this parameter, set the XCVR Page Mode

section to Detailed.

8B10B Encoder Used

Enter whether or not 8B/10B encoder/decoder is

used.
To enter this parameter, set the XCVR Page Mode

section to Detailed.

Channel Power (W)

This shows the total power of the GXB transmitter

channel PMA and GXB receiver channel PMA

blocks for all channels (in watts). This value is

automatically calculated.

CCU Power (W)

This shows the total power of the GXB PLLs and

control circuitry for all channels (in watts). This

value is automatically calculated.

XCVR Power (W)

This shows the sum of the channel power and CCU

power (in watts). This value is automatically

calculated.

PCS/HIP Power (W)

This shows the total power of the GXB transmitter

channel PCS, GXB receiver channel PCS, and PCIe

hard IP blocks for all channels (in watts). This value

is automatically calculated.

User Comments

Enter any comments. This is an optional entry.

Values of some settings in the XCVR worksheet are restricted for one of the following reasons:
• The setting value is restricted due to the selections made for other settings.

• Changing the setting would not have a significant impact on power, given the selected values of other

settings.

For more information about the transceiver architecture of the supported device families, refer to the

“Transceiver Architecture” chapter in the respective device handbook.

HMC Worksheet

The EPE spreadsheet version 11.1 introduces the HMC worksheet. Each row in the HMC worksheet

represents a single instance of the HMC interface. Enter the information for HMC instances in different

rows, even if some of the HMC instances have the same configuration. Specify the following information

for each HMC instance:
• Clock frequency (in MHz)

• DRAM interface width

• Number of command port

• Fabric interface width
The HMC worksheet is only applicable to Arria V and Cyclone V device families with HMC controllers.