Power breakout for multiple voltage supplies, Power regulator settings, Enpirion worksheet – Altera PowerPlay Early Power Estimator User Manual

Page 50: Power breakout for multiple voltage supplies -40, Power regulator settings -40, Enpirion worksheet -40

Advertising
background image

Power Breakout for Multiple Voltage Supplies

For V

CCIO

and V

CCPD

, the minimum current requirement reported for I

CCIO

and I

CCPD

respectively has

the same value for each voltage rail used in your design.
These values are based on all I/O pins in the device being powered by the same voltage rail, thus the

minimum current requirement is repeated for each unique voltage rail used by V

CCIO

and V

CCPD

.

To better estimate the minimum current requirements for I

CCIO

and I

CCPD

based on your device and

design usage, you can use the following equations:
• [(Number of I/O pins powered by V

CCIO

voltage) / (number of total I/O pins in the device)] ×

(Minimum supply current) × (1.10)

• [(Number of I/O pins powered by V

CCPD

voltage) / (number of total I/O pins in the device)] ×

(Minimum supply current) × (1.10)

Repeat the formula for each V

CCIO

voltage and V

CCPD

voltage used in your design. The number of I/O

pins powered by V

CCIO

and V

CCPD

voltage represents the count of both used and unused I/O pins in I/O

banks powered by a particular voltage. The minimum supply current is the value provided in the power

estimation tools for I

CCIO

and I

CCPD

.

The 1.10 scaling factor is provided as additional guardband and must be included for your power

estimation.

Power Regulator Settings

Regulator groups consist of rails that can be combined and supplied by a single regulator. A manual entry

here can move a rail from one group to another or create a new group. This may be necessary to correct

grouping errors that may occur.

Related Information

Power Tree Design

on page 3-7

Enpirion Worksheet

Enpirion power devices are available to satisfy the power requirements for the power rails on Altera FPGA

devices. Power devices are selected based on load current, input and output voltages, and power-delivery

configuration.
Each row in the Regulator Selection table represents the power solution for a single power group. The

power groups are created by combining rails that can be allowably supplied from the same source.

Enpirion device selection is enabled when the Main worksheet for the Maximum Power Characteristics

and the Regulator Group section of the Report worksheet are set up correctly with no grouping errors.
In the following figure, a 12-V off-line regulator supplies input power for Groups 1 and 5. The 3-V

regulator supplying Group 5 also acts as an intermediate bus supplying input power for Groups 2, 3, and

4.

3-40

Power Breakout for Multiple Voltage Supplies

UG-01070

2015.01.20

Altera Corporation

PowerPlay Early Power Estimator Worksheets

Send Feedback

Advertising