11 str4/8 hardware manual – Applied Motion STR4 User Manual

Page 11

Advertising
background image

11

STR4/8 Hardware Manual

920-0030J

5/12/2015

Switch

Motor

Drive Current

Amps, peak of

sine

Max Power Supply Current (A)

24VDC

48VDC

60VDC

0

reserved for custom motors

1
2
3

HT23-603

6

4.4

4.0

4.0

4

HT23-394/594

3.4

1.9

2.0

n/a

5

HT23-398/598

5

3.2

3.3

n/a

6

HT23-401/601

5

3.2

3.4

n/a

7

HT24-100

3.36

2.6

2.3

2.0

8

HT24-105

4.8

5.2

3.2

2.7

9

HT24-108

4.8

4.3

3.4

2.9

A

HT34-485

8

5.1

5.0

5.0

B

HT34-486

8

5.2

4.6

4.4

C

HT34-487

8

5.2

5.4

5.3

D

HT34-504

7.56

4.8

4.2

4.0

E

HT34-505

7.56

4.4

4.2

4.2

F

HT34-506

6.72

3.5

3.2

3.3

Table 2: STR8 Power Supply Current

All motors connected in parallel, except HT24 which have four leads.

Regeneration

If you plan to use a regulated power supply you may encounter a problem with regeneration.

If you rapidly decelerate a load from a high speed, much of the kinetic energy of that load is

transferred back to the power supply. This can trip the overvoltage protection of a switching

power supply, causing it to shut down. If you have a high inertia load running at high speed an

unregulated supply may be better. It has large capacitors for storing energy coming back from

the drive. They are also less expensive. See previous section on

Connecting the Power Supply

for details on the RC-050 regeneration clamp.