Step 6: step pulse type, 22 str4/8 hardware manual – Applied Motion STR4 User Manual

Page 22

Advertising
background image

22

STR4/8 Hardware Manual

920-0030J

5/12/2015

Step 6: Step Pulse Type

Most indexers and motion controllers provide motion commands in the “Step and Direction”

format. The Step signal pulses once for each motor step and the direction signal commands

direction. However, a few PLCs use a different type of command signal: one signal pulses once

for each desired step in the clockwise direction (called STEP CW), while a second signal pulses

for counterclockwise motion (STEP CCW).

The STR drives can accept this

type of signal if you remove the

drive cover and move jumper

S3 from the “1-2” position to

the “1-3” position. In STEP CW/

STEP CCW mode, the CW signal

should be connected to the STEP

input and the CCW signal to the

DIR input.

1-2: Step & Direction

1-3: STEP CW & STEP CCW

S3 Jumper settings

Advertising