If you plan to use a regulated power supply you may encounter a problem with regeneration.

If you rapidly decelerate a load from a high speed, much of the kinetic energy of that load is

transferred back to the power supply. This can trip the overvoltage protection of a switching

power supply, causing it to shut down. We offer the RC-050 “regeneration clamp” to solve this

problem. If in doubt, buy an RC-050 for your first installation. If the “regen” LED on the RC-050

never flashes, you don’t need the clamp.

RC-050 Regen Clamp

Power Supply and Ground Connections

Locate fuse in-line with “+” connection

regen LED