Alarm codes, Connector diagrams – Applied Motion STR4 User Manual

Page 46

Advertising
background image

Alarm Codes

In the event of a drive fault or alarm, the green LED will flash one or two times, followed by a series of red flashes. The pattern

repeats until the alarm is cleared. Faults disable the motor and can be cleared by cycling power to the drive or toggling the

enable input. The “power supply voltage too low alarm” does not disable the motor and will self-clear after 30 seconds. It can

be cleared sooner by cycling power to the drive or toggling the enable input.

404 Westridge Drive Watsonville, CA 95076

Tel (831) 761-6555 (800) 525-1609 Fax (831) 761-6544

www.applied-motion.com

Power and Motor Connector

Signal Connector

Connector Diagrams

Code

Error

solid green

no alarm, motor disabled

flashing green no alarm, motor enabled
flashing red

configuration or memory error; Contact factory for assistance.

1 green, 4 red power supply voltage too high fault
1 green, 5 red over current / short circuit fault
1 green, 6 red open motor winding fault
2 green, 3 red internal voltage out of range fault
2 green, 4 red power supply voltage too low alarm

V+ V

A

B+ B

A+

STEP+ STEP

DIR

EN+ EN

FAULT

+

FAULT

DIR+

920-0030G

12/12/2012

Advertising
This manual is related to the following products: