Analog input, 33 stm23 hardware manual – Applied Motion STM23C-3CE User Manual

Page 33

Advertising
background image

Analog Input

The STM23S/Q/IP drives feature an analog input (not available on STM23C drives). The input can accept a signal

range of 0 to 5 VDC. The drive can be configured to operate at a speed or position that is proportional to the

analog signal. Use the

ST Configurator

software to set the signal range, offset, dead-band and filter frequency. The

STM23 drives provide a 5 volt DC, 50 mA output labeled +5V that can be used to power external devices such as

potentiometers. It is not the most accurate supply for reference; for more precise readings use an external supply

that can provide the desired accuracy.

Connecting a Potentiometer to the Analog Input

inside drive

AIN

GND

Signal

Conditioning

+5V

50ma Limit

I/O

Connec

tor

1-10k Ohm

potentiometer

cw

ccw

GND

AIN

+5V

33

STM23 Hardware Manual

920-0021F