Installation – Desa VRL30PR User Manual

Page 13

Advertising
background image

www.desatech.com

110021-01M

13

Area of Various Standard Round Flues

Diameter (ins.)

Area (sq. ins.)

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. ins.)

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

Figure 10 - Attaching Damper Clamp

Manufactured

Fireplace

Masonry Fireplace

Damper

Damper
Clamp

Damper

Damper

INSTALLING DAMPER CLAMP
ACCESSORY FOR VENTED
OPERATION

(Remote-Ready Models Only)

Note:

When used as a vented heater, appliance

must be installed only in a solid-fuel burning

fireplace with a working flue and constructed of

noncombustible material.
If your heater is a manually-controlled model, you

may use this heater as a vented product. There

are three reasons for operating your heater in the

vented mode.
1. The fireplace does not meet the clearance

to combustibles requirements for vent-free

operation.

2. State or local codes do not permit vent-free

operation.

3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you

must permanently open chimney flue damper. You

must install the damper clamp accessory (to order,

see Accessories, page 41). This will insure vented

operation (see Figure 10). The damper clamp will

keep damper open. Installation instructions are

included with clamp accessory.
See chart below for minimum permanent flue

opening you must provide. Attach damper clamp

so the minimum permanent flue opening will be

maintained at all times.

INSTALLATION

Continued

INSTALLING HEATER BASE
ASSEMBLY

CAUTION: Do not remove the

data plates attached to the heater

base assembly. The data plates

contain important warranty and

safety information.

WARNING: If installing in a

sunken fireplace, special care

is needed. You must raise the

fireplace floor to allow access to

heater control panel. This will in-

sure adequate air flow and guard

against sooting and controls be-

ing damaged. Raise fireplace floor

with noncombustible material.

Make sure material is secure.

CAUTION: Do not pick up

heater base assembly by the

burner. This could damage

heater. Only handle base as-

sembly by grates.

Advertising