OPTIONAL POSITIONING

OF THERMOSTAT

SENSING BULB

FOR MASONRY AND FACTORY-
BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room tem-

perature drops to a lower than ideal comfort level

before the log set comes back on, you may want

to reposition the thermostat sensing bulb.
The thermostat sensing bulb is located near the

gas valve assembly on the mounting bracket.

This location allows the thermostat to keep the

room temperature at an ideal comfort level for

most fireplace applications. For positioning the

thermostat sensing bulb elsewhere, an adhesive-

backed mounting clip is available.
1. Locate the gas valve assembly and thermostat

sensing bulb (see Figure 43).

2. Gently pull thermostat sensing bulb free from

the retaining clamp.

IMPORTANT:

Do not force or bend the

thermostat sensing bulb or capillary.

3. The thermostat sensing bulb may be located

to the lower right front side of fireplace. De-

termine location of sensing bulb, but do

not mount sensing bulb until step 4. If you

have a masonry fireplace, see Figure 45

for location. If you have a factory-built

metal fireplace, see Figure 46 for location.

If your fireplace has glass doors, position

sensing bulb directly behind door gap on right

bottom side (see Figure 47).

4. The mounting clip must be a minimum of 3"

from bottom of fireplace to prevent crimping

of capillary. Once you have decided on a

location, clean the area thoroughly. Remove

the paper backing from the adhesive on back

of mounting clip. Press the clip into the new

location so that the thermostat sensing bulb

will be positioned vertically with the capillary

at the bottom (see Figure 48, page 33). Slide

the thermostat sensing bulb into the clip.

IMPORTANT:

Do not crimp capillary.

Figure 44 - Adhesive-backed Mounting Clip

Adhesive-backed
Mounting Clip

Figure 45 - Locating Thermostat Sensing

Bulb on Masonry Fireplace

Thermostat
Sensing Bulb

Thermostat
Sensing Bulb

Figure 46 - Locating Thermostat Sensing

Bulb on Factory-built Metal Fireplace

Adhesive-backed
Mounting Clip

Glass Doors

Figure 47 - Installing Thermostat Sensing

Bulb Behind Glass Doors

Thermostat
Sensing Bulb

Adhesive-
backed
Mounting Clip

Figure 43 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Gas Valve
Assembly

Thermostat
Sensing Bulb

Retaining
Clamp