Troubleshooting – Desa VRL30PR User Manual

Page 29

Advertising
background image

www.desatech.com

110021-01M

29

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

ODS/pilot lights but flame goes

out when control knob is re-

leased

One or more burners do not light

after ODS/pilot is lit

Delayed ignition of one or more

burners

Burner backfiring during com-

bustion

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep con-

trol knob pressed in 30 seconds

3. Wait one minute for safety in-

terlock system to reset. Repeat

ignition operation

4. Fully open equipment shutoff

valve

5. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see

Cleaning and Maintenance,

page 26) or replace ODS/pilot

assembly

6. Hand tighten until snug, then

tighten 1/4 turn more

7. Replace pilot assembly

8. Replace control valve

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 26) or

replace burner orifice(s)

3. Contact qualified service person

4. Reconnect leads (see Wiring

Diagram, page 33)

5. Replace battery in transmitter

and receiver

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner(s) (see Cleaning

and Maintenance, page 26) or

replace burner orifice(s)

3. Contact qualified service person

1. Clean burner (see Cleaning

and Maintenance, page 26) or

replace burner orifice

2. Replace damaged burner

3. Replace gas regulator

POSSIBLE CAUSE

1. Control knob not fully pressed in

2. Control knob not pressed in

long enough

3. Safety interlock system has

been triggered (Thermostat-

Controlled Models only)

4. Equipment shutoff valve not

fully open

5. Pilot flame not touching ther-

mocouple, which allows ther-

mocouple to cool, causing

pilot flame to go out. This

problem could be caused by

one or both of the following:

A) Low gas pressure

B) Dirty or partially clogged

ODS/pilot

6. Thermocouple connection

loose at control valve

7. Thermocouple damaged

8. Control valve damaged

1. Inlet gas pressure is too low

2. Burner orifice(s) clogged

3. Mislocated crossover tube

4. Thermopile leads disconnected

or improperly connected (Re-

mote-Ready Models Only)

5. Burners will not come on in

remote position (Remote-

Ready Models Only)

1. Manifold pressure is too low

2. Burner orifice(s) clogged

3. Mislocated crossover tube

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective