Installation Items Needed
Before installing heater, make sure you have the

items listed below.
• external regulator (supplied by installer)
• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• test gauge connection *
• sediment trap
• tee joint
• pipe wrench
* A CSA design-certified equipment shutoff valve

with 1/8" NPT tap is an acceptable alternative to

test gauge connection. Purchase the optional CSA

design-certified equipment shutoff valve from your

dealer. See Accessories, page 41.
For propane/LP gas, the installer must supply an

external regulator. The external regulator will

reduce incoming gas pressure. You must reduce

incoming gas pressure to between 11 and 14 inches

of water. If you do not reduce incoming gas pres-

sure, heater regulator damage could occur. Install

external regulator with the vent pointing down

as shown in Figure 13. Pointing the vent down

protects it from freezing rain or sleet.

CAUTION: Use only new, black

iron or steel pipe. Internally-tinned

copper tubing may be used in

certain areas. Check your local

codes. Use pipe of 1/2" diameter or

greater to allow proper gas volume

to heater. If pipe is too small, undue

loss of volume will occur.

INSTALLATION

Continued

Figure 13 - External Regulator With Vent

Pointing Down

Installation must include a equipment shutoff valve,

union and plugged 1/8" NPT tap. Locate NPT tap

within reach for test gauge hook up. NPT tap must

be upstream from heater (see Figure 14 or 15, page

16, depending on your model).
IMPORTANT:

Install equipment shutoff valve in an

accessible location. The main gas valve is for turn-

ing on or shutting off the gas to the appliance.
Check your building codes for any special re-

quirements for locating equipment shutoff valve

to fireplaces.
Apply pipe joint sealant lightly to male NPT

threads. This will prevent excess sealant from

going into pipe. Excess sealant in pipe could result

in clogged heater valves.

WARNING: Use pipe joint

sealant that is resistant to liquid

petroleum (LP) gas.

We recommend that you install sediment trap

in supply line as shown in Figure 14 or 15, page

16, depending on your model. Locate sediment

trap where it is within reach for cleaning. Install

in piping system between fuel supply and heater.

Locate sediment trap where trapped matter is not

likely to freeze. A sediment trap traps moisture and

contaminants. This keeps them from going into

heater controls. If sediment trap is not installed or is

installed wrong, heater may not run properly.

CAUTION: Avoid damage to

regulator. Hold gas regulator with

wrench when connecting it to gas

piping and/or fittings (Thermo-

stat-Controlled Models Only).

CAUTION: Avoid damage to

gas control. Hold gas control

with wrench when connecting

it to gas piping and/or fittings

(Remote-Ready Models Only).

Propane/LP
Supply Tank

External
Regulator

Vent
Pointing
Down