2 single operation mode of skp 2-10 – AXING SKP 2-10 User Manual

Page 7

Advertising
background image

Operation Instructions SKP 2-10

Chapter 2: Installation and connection

31.05.12

© AXING AG • Swizzerland • Reserving change in design and type

7

2.2

Single operation mode of SKP 2-10

Before installing modules, the power supply must be switched off. Ground the module acc. to
EN 50083-1, EN 60728-11:2010 in order to avoid dangerous overvoltages (attention: risk of fire/death).
Use the grounding screw attached to the device (see 12 in Fig. 2).
When using the SKP 2-10 in single operation mode, the power is supplied via the DC socket (see 9 in
fig. 2 on page 5). A separate power supply unit SKZ 5-01

1

is required for it. More units are connected by

means of the DC loop-through. One DC connection cable SKZ 4-00 is included in the delivery of the
SKP 2-10. Max. 4 pieces SKP 2-10 may be connected together in single operation mode.

In single operation mode of the SKP 2-10 the outputs of the twin cassettes must be combined together
with splitters. The splitters (SKV 2..8-00) may be used in connection with F-double sockets (CFA 3-00).

1

SKZ 5-01 to supply up to 4 modules/SKZ 5-03 to supply up to 2 modules

Fig. 4: Assembly and
connection of a single twin
module

Fig. 5: Assembly and

connection of up to four twin
modules