We recommend that you install a sediment trap in

supply line as shown in Figure 15. Locate sediment

trap where it is within reach for cleaning. Install in

piping system between fuel supply and fireplace.

Locate sediment trap where trapped matter is not

likely to freeze. A sediment trap traps moisture

and contaminants. This keeps them from going

into fireplace gas controls. If sediment trap is not

installed or is installed wrong, fireplace may not

run properly.

Figure 15 - Gas Connection

* Purchase the optional CSA design-certified

equipment shutoff valve from your dealer. See

Accessories, page 37.

CONNECTING FIREPLACE TO GAS
SUPPLY

Installation Items Needed
• 5/16" hex socket wrench or nut-driver
• Phillips screwdriver
• sealant (resistant to propane/LP gas, not

provided)

1. If fireplace screen and floor are still installed,

see Removing Fireplace Screen and Floor

Assembly, page 9.

2. Route gas line (provided by installer) from

equipment shutoff valve to fireplace. Route

flexible gas supply line through one of the

access holes.

Natural
From Gas Meter
(5" W.C. to
10.5" W.C.
Pressure)

Propane/LP
From External
Regulator (11"
W.C. to 14 "
W.C. Pressure

CSA Design-Certified
Equipment Shutoff Valve
With 1/8" NPT Tap*

3" Minimum

Sediment Trap

Pipe Cap Tee
Nipple

Joint

INSTALLATION

Continued

NOTICE: Most building codes

do not permit concealed gas

connections. A flexible gas line

is provided to allow accessibility

from the fireplace (see Figure 16).

The flexible gas supply line con-

nection to the equipment shutoff

valve should be accessible.

3. Attach the flexible gas line to gas supply (see

Figure 16). Check tightness of flexible gas

line attached to gas regulator of fireplace (see

Figure 16).

4. Check all gas connections for leaks. See

Checking Gas Connections.

5. Replace fireplace floor assembly. Feed flexible

gas line into fireplace base area while replacing

fireplace floor assembly. Make sure the entire

flexible gas line is in fireplace base area.

Note:

Be careful of wires and components on

underside of fireplace floor. Reattach fireplace

floor assembly with screws removed in step

3 of Removing Fireplace Screen and Floor

Assembly, page 9.

Figure 16 - Attaching Gas Lines Together

From Gas Meter (Natural)
From External Regulator
(Propane/LP)

Flexible Gas Line
from Fireplace
Gas Regulator

To Fireplace Gas
Regulator

Equipment Shutoff
Valve Provided by
Installer

CHECKING GAS CONNECTIONS

WARNING: Test all gas piping

and connections, internal and

external to unit, for leaks after

installing or servicing. Correct

all leaks at once.

WARNING: Never use an

open flame to check for a leak.

Apply a noncorrosive leak detec-

tion fluid to all joints. Bubbles

forming show a leak. Correct all

leaks at once.