Operating fireplace – Desa VTGF33NRA User Manual

Page 22

Advertising
background image

www.desatech.com

110112-01C

22

Automatic Ignitor
Electrode

Pilot Burner

Figure 38 - Pilot (Propane/LP Gas

Shown)

Manual
Ignitor
Electrode

Thermocouple

OPERATING FIREPLACE

Continued

B. Using Hand-Held Wireless Remote
Control

1. Set manual ignition bypass switch on

control panel to OFF position (automatic

ignition position).

2. Wait five (5) minutes to clear out any gas.

Smell for gas around heater and near floor.

If you smell gas, STOP! Follow “B” in the

safety information on warnings plate. If you

donʼt smell gas, go to the next step.

3. Point remote control toward the lower

front of fireplace and push both buttons at

the same time. Hold for 6 seconds. The gas

valve will open and electronic ignition will

begin sparking to light the pilot. Note: You

will be able to hear a clicking sound during

this process. LED on wall switch will light.

Note:

You may be running this heater for

the first time after connecting to gas supply

or at the start of your heating season. If so,

the ON button may need to be pressed again.

This will allow air to bleed from gas system.

If several attempts to light pilot fail, contact

a qualified service person or gas supplier

for repairs. Until repairs are made, light

and operate manually (see Manual Lighting

Instructions for Electrical Power Outage).

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater - Wall Switch

Push ON/OFF button on wall switch once.
Shutting Off Heater - Wireless Remote
Control

Point remote control toward lower front of fire-

place and push both buttons at the same time.

MANUAL LIGHTING

INSTRUCTIONS FOR

ELECTRICAL POWER

OUTAGE

WARNING: You must oper-

ate this heater with the fireplace

screen in place. Make sure fire-

place screen is in place before

running heater.

NOTICE: During initial operation of

new heater, burning logs will give

off a paper-burning smell. Open

damper or window to vent smell.

This will only last a few hours.

Because this fireplace has an electronic ignition

system, in the event there is a loss of power, it

will be necessary to manually light the pilot with

the piezo ignitor. After the pilot is lit, the main

burner will light automatically.

1. Follow steps 1 through 3 under Normal

Lighting Instructions, page 21.

2. Set manual ignition bypass switch on con-

trol panel to ON position (manual ignition

position). See Figure 39, page 23.

3. The pilot is attached to the rear of the front

burner. You will be able to see the pilot

and spark electrode without removing the

screen or logs.

Manual
Ignition
Bypass
Switch
(Up is for
Remote
Control)

ON/OFF
Button

HI/LO
Button

Wall Switch
Assembly

Figure 37 - Control Locations

LED

4. When pilot flame is lit, the thermocouple is

heated by the flame. When thermocouple

becomes hot (5 to 15 seconds), main burner

will automatically light on high flame.

5. To lower flame, point remote control toward

lower front of fireplace and push HI/LO

button once.

Note:

This fireplace does not have a pilot-

only mode.