Installation, Continued built-in fireplace installation – Desa VTGF33NRA User Manual

Page 17

Advertising
background image

www.desatech.com

110112-01C

17

Figure 23 - Inserting Fireplace Into

Cabinet Mantel

INSTALLATION

Continued

BUILT-IN FIREPLACE INSTALLATION

Built-in installation of this fireplace involves

installing fireplace into a framed-in enclosure.

This makes the front of fireplace flush with wall.

If installing a mantel above the fireplace, you must

follow the clearances shown in Figure 27. Follow

the instructions below to install the fireplace in

this manner.

Actual

Framing

Height

32

3

/

8

"

33"

Front Width

34

5

/

16

"

35

1

/

2

"

Depth

16

11

/

16

"

17

3

/

4

"

1. Frame in rough opening. Use dimensions shown

in Figure 24 for the rough opening. If installing

in a corner, use dimensions shown in Figure 25

for the rough opening. The height is 33" which

is the same as the wall opening above.

2. Install and properly ground GA3555, three-

prong 120 volt electrical outlet, in fireplace.

Follow instructions included in kit (see Ac-

cessories, page 37).

3. If not already completed, install gas piping to

fireplace location. This installation includes an

approved flexible gas line (if allowed by local

codes) after the equipment shutoff valve. The

flexible gas line must be the last item installed

on the gas piping. See Installing Gas Piping

to Fireplace Location, page 13.

4. Carefully set fireplace in front of rough opening

with back of fireplace inside wall opening.

5. Attach flexible gas line to gas supply. See Con-

necting Fireplace to Gas Supply, page 14.

6. Plug electrical cord(s) into electrical outlet

installed in step 2.

7. Carefully insert fireplace into rough opening.
8. Attach fireplace to wall studs using nails or

wood screws through holes in nailing flange

(see Figure 26).

9. Check all gas connections for leaks. See

Checking Gas Connections, pages 14.

10. Install brass trim. See Assembling and Attach-

ing Optional Brass Trim, page 18.

35

1

/

2

"

17

3

/

4

"

33"

39

3

/

8

"

27

7

/

8

"

55

5

/

8

"

35

1

/

2

"

Figure 24 - Rough Opening for Installing

in Wall

Figure 25 - Rough Opening for Installing

in Corner

Figure 26 - Attaching Fireplace to Wall

Studs

Nailing
Flanges

Nails or
Wood
Screws

Advertising