TROUBLESHOOTING

Continued

POSSIBLE CAUSE

1. No power available to fire-

place

2. Manual ignition bypass

switch not in OFF position

3. Wall switch wire harness is

disconnected

1. Burner orifice clogged

2. Inlet gas pressure is too low

1. Manifold pressure is too

low

2. Burner orifice clogged

1. Burner orifice is clogged or

damaged

2. Damaged burner

3. Gas regulator defective

1. Not enough air

2. Gas regulator defective

3. Residues from manufacturing

processes and logs curing

1. Not enough combustion/ven-

tilation air

1. Turning control knob to HI

position when burner is cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice

REMEDY

1. Make sure power cord is

plugged into an electrical

outlet and outlet has power

2. Place manual ignition bypass

switch in OFF position

3. Check continuity of wall

switch wire harness. Make

sure plug on wall switch wire

harness is fully inserted into

socket on circuit board in fire-

place. Replace if necessary

1. Clean burner (see Cleaning

and Maintenance, page 25) or

replace burner orifice

2. Contact local gas company

1. Contact local natural or pro-

pane/LP gas company

2. Clean burner (see Cleaning

and Maintenance, page 25) or

replace burner orifice

1. Clean burner (see Cleaning

and Maintenance, page 25) or

replace burner orifice

2. Replace damaged burner

3. Replace regulator

1. Check burner for dirt and

debris. If found, clean burner

(see Cleaning and Mainte-

nance, page 25)

2. Replace regulator

3. Problem will stop after a few

hours of operation

1. Refer to Air for Combustion

and Ventilation requirements

(page 5)

1. Turn control knob to LO position

and let warm up for a minute

2. Operate burner until air is

removed from line. Have gas

line checked by local natural

or propane/LP gas company

3. Observe minimum installation

clearances (see page 9)

4. Clean burner (see Cleaning

and Maintenance, page 25) or

replace burner orifice

OBSERVED PROBLEM

When wall switch button is

pressed, there is no response

from fireplace

Burner does not light after ODS/

pilot is lit

Delayed ignition burner

Burner backfiring during com-

bustion

Slight smoke or odor during initial

operation

Moisture/condensation noticed

on windows

Heater produces a whistling noise

when burner is lit