Operating fireplace – Desa VTGF33NRA User Manual

Page 23

Advertising
background image

www.desatech.com

110112-01C

23

Figure 39 - Control Locations

Manual Ignition
Bypass Switch
(Down is ON)

ON/OFF Button

HI/LO Button

Piezo Ignitor

Wall
Switch

LED

LED

Magnetic Manual
Override Handle

Gas
Valve

OPERATING FIREPLACE

Continued

4. Place the magnetic manual override handle,

provided with this unit, on the end of the

gas valve stem (see Figure 39).

5. Turn the override handle fully counter-

clockwise

to the PILOT position.

The handle will not stop but will begin

to slip when you have fully turned to the

PILOT position.

6. While holding the valve handle in the

PILOT position, press and release piezo

ignitor button (see Figure 39). This will light

the pilot. If needed, keep pressing ignitor

button until pilot lights.

7. When pilot flame is lit, hold manual over-

ride handle until thermocouple heats (ap-

proximately 5 to 15 seconds). If pilot goes

out, repeat process. If several attempts

to light the pilot fail, contact a qualified

service person or gas supplier for repairs.

8. When thermocouple is heated, release

override handle. The main burner will im-

mediately light on high flame. Adjust flame

size by turning override handle.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater When Manually Lit

Set manual ignition bypass switch on control

panel to OFF (automatic ignition position).

This will cause the controls to shut down the

fireplace.

OPTIONAL BLOWER

OPERATION

Locate the blower switch by opening lower

louver on fireplace. Blower switch is located at

lower left inside louver door.
Note:

It is safe to operate fireplace with blower

turned off. However, the blower helps distribute

heated air from the fireplace.

Follow installation instructions included with

the blower accessory.

OPERATING

FAN

This blower has three settings: ON, OFF, and

AUTO. In the ON position, the blower will oper-

ate constantly. In the OFF position, the blower

will not operate. In the AUTO position, the

blower will start when the thermostat senses a

sufficient increase in firebox temperature.
Note:

Your fireplace and thermostat blower

will not turn on and off at the same time. The

fireplace may run for several minutes before the

blower turns on. After the heater modulates to

the pilot position, the blower will continue to

run. The blower will shut off after the firebox

temperature decreases.
Note:

It is safe to operate fireplace with blower

turned off. However, the blower helps distribute

heated air from the fireplace.

Figure 40 - AUTO/OFF/ON Switch

AUTO/OFF/ON
Switch

Piezo Ignitor

Fan Switch