Pse90 flat screen electric wall mount – Future Automation PSE90 User Manual

Page 13

Advertising
background image

Installation:

Electrical connection

+ (

+ (

Page 1

2 of 17 // email [email protected] tel: 44 0) 1438 833577 fax: 44 0) 1438 833565

PSE90 Flat Screen Electric Wall Mount

Contact Closure

Use an RJ45 connector in the
CCI socket on the control box
to operate via contact closure





SLQV

LED 1
LED 2
LED 3

LED 4
LED 5

CONTACT CLOSURE INPUT

NOTE:
Earlier versions of the control board
may not have these contact closure
LED indicators.

568A

568B

1

12V SUPPLY

12V SUPPLY - CURRENT LIMITED

W/G

W/O

2

12V LATCH

When 12V attached, device will go OUT to PRESET

position. When 12V removed, device will go IN.

G

O

3

GROUND

GROUND

W/O

W/G

4

DEVICE LATCH

Short to GROUND (pin 3), device will go OUT to PRESET

position, remove short device will go IN.

BL

BL

5

PIN 4 NOT USED

W/BL

W/BL

6

DEVICE STOP

Momentary short to GROUND (pin 3), stops device in

current position.

O

G

7

DEVICE OUT

Momentary short to GROUND (pin 3), makes device go

OUT.

W/BR

W/BR

8

DEVICE IN

Momentary short to GROUND (pin 3), makes device go

IN.

BR

BR

PIN

DESCRIPTION

ACTION

WIRE / CABLE

Advertising