4.1 Troubleshooting

222

Installation Manual

4.1

Troubleshooting

4.1.1

Installation

PROBLEM

PROBABLE CAUSE

SOLUTION

Extension does not operate.

Bad extension card.

•

Exchange the card for a known working
one.

Bad connection between the
Hybrid IP-PBX and telephone.

•

Take the telephone and plug it into the
same extension port using a short
telephone cord. If the telephone works,
then the connection between the Hybrid
IP-PBX and the telephone must be
repaired.

A telephone with an A-A1 relay
is connected.

•

Use a 2-wire cord.

•

Set the A-A1 relay switch of the
telephone to the "OUT" or "OFF"
position.

Bad telephone.

•

Take the telephone and plug it into
another extension port that is working.
If the telephone does not work, replace
the telephone.

Wrong type of PSU.

•

Replace the PSU with the appropriate
type.

The Hybrid IP-PBX does not
operate properly.

•

Press the Reset Button (refer to "4.1.4
Using the Reset Button"
).

•

Turn off the power switch, and then turn
it back on.

•

Turn off the power switch, and then
unplug the Hybrid IP-PBX. After 5
minutes, plug the Hybrid IP-PBX back
in, and turn the power switch back on.

Noise on external paging.

Induced noise on the wire
between the Hybrid IP-PBX and
the amplifier.

•

Use a shielded cable as the connection
wire between the Hybrid IP-PBX and
amplifier. A short shielded cable is
recommended.

Distorted external music.

Excessive input level from
external music source.

•

Decrease the output level of the
external music source by using the
volume control on the music source.

Alternate Calling—Ring/Voice
and Live Call Screening (LCS)
do not function as set when using
a Wireless Phone (KX-T7880/
KX-T7885/KX-TD7894/KX-
TD7895).

Voice-calling mode and Hands-
free mode with LCS are not
available with Wireless Phones.

•

Switch the calling mode to ring-calling.

•

Set the LCS mode to "Private".