D-Link KX-TDA100 User Manual

Page 237

Advertising
background image

4.1 Troubleshooting

Installation Manual

237

310*

Port Link Failure

•

Voice Processing System
malfunction

•

Ports defective on optional
service card: DHLC, DLC

•

Check the Voice Processing System

•

See if the corresponding optional
service card is installed properly

•

Replace the corresponding optional
service card

320

IP-GW H.323
Dummy Call Test
Error

•

Detection of IP-GW H.323
Dummy Call Test error

•

Replace the corresponding optional
service card

•

Collect the log data of IP-GW (refer to
the documentation for the IP-GW card)

321

IP-GW Gatekeeper
Error

•

Detection of Gatekeeper
access error

•

Check the IP address setting of
Gatekeeper

•

Check whether the Gatekeeper is
connected to the network and work
properly

•

Check the route to the Gatekeeper

322

IP-GW Gatekeeper
Registration Error

•

Gatekeeper Registration
is failed

•

Check the Gatekeeper setting

323

IP-GW SDRAM
Failure

•

Detection of IP-GW
SDRAM error

•

Replace the corresponding optional
service card

324

IP-GW DPRAM
Failure

•

Detection of IP-GW
DPRAM error

•

Replace the corresponding optional
service card

325

IP-GW LAN Chip
Failure

•

Detection of IP-GW LAN
Chip failure

•

Replace the corresponding optional
service card

•

Collect the log data of IP-GW (refer to
the documentation for the IP-GW card)

326

IP-GW Stop

•

IP-GW is stopped from a
remote maintenance PC

•

This information is logged when IP-GW
is stopped from a remote maintenance
PC

330

Loop current
detection error

•

Detection of LCOT loop
current error

•

Change the corresponding trunk status
back to In Service

•

Enter the feature number to clear Busy
Out status

•

The trunk status is automatically
changed back to In Service by system
diagnosis performed at a
preprogrammed time every day

350

IP-unit SDRAM bit
error

•

Optional service card
malfunction: IP-EXT

•

The IP-EXT card will be rebooted
automatically if the error is temporary

•

Replace the corresponding IP-EXT
card if the card is not rebooted

351

IP-unit download
data check-sum error

352

IP-unit DSP failure

•

Optional service card
malfunction: IP-EXT

•

Replace the corresponding optional
service card

Error Code

Error Message

PROBABLE CAUSE

SOLUTION

Advertising