5 frame earth connection – D-Link KX-TDA100 User Manual

Page 48

Advertising
background image

2.2 Installation of the Hybrid IP-PBX

48

Installation Manual

2.2.5

Frame Earth Connection

IMPORTANT

Connect the frame of the Hybrid IP-PBX to earth.

•

Be sure to comply with applicable local regulations (e.g., law, guidelines).

•

Proper earthing (connection to earth) is very important to protect the Hybrid IP-PBX from the bad
effects of external noise or to reduce the risk to the user of electrocution in the case of lightning strike.

•

The earthing wire of the AC cable has an effect against the external noise and lightning strikes, but it
may not be enough to protect the Hybrid IP-PBX. A permanent connection between earth and the earth
terminal of the Hybrid IP-PBX must be made.

1.

Loosen the screw.

2.

Insert an earthing wire (user-
supplied)*.

3.

Tighten the screw.

4.

Connect the earthing wire to
earth.

* For earthing wire, green-and-yellow insulation is required, and the cross-sectional area of the conductor

must be more than 0.75 mm

2

or 18 AWG.

Screw

To earth

Earthing
wire