D-Link KX-TDA100 User Manual

Page 89

Advertising
background image

2.4 Installation of the Trunk Cards

Installation Manual

89

BNC (coaxial) Connector (RX)

LED Indications

Maximum Cabling Distance of Extension Connection

The maximum distance of the extension cable that connects the E1 cards is shown below:

No.

Signal Name

Level [V]

Function

1

RX-

(-)

Receive data (-)

2

RX+

(+)

Receive data (+)

Indication

Colour

Description

CARD STATUS

Green/Red

Card status indication

•

OFF: Power Off

•

Green ON: Normal (all ports are idle)

•

Green Flashing (60 times per minute): Normal (a port is in use)

•

Red ON: Fault (includes reset)

•

Red Flashing (60 times per minute): Out of Service

SYNC-ERR

Red

Non-synchronisation status indication

•

OFF: Normal

•

ON: Out of synchronisation

RAI

Red

RAI signal status indication

•

OFF: Normal

•

ON: Alarm (Clock Slave)

•

Flashing (60 times per minute): Alarm (Clock Master)

AIS

Red

AIS status indication

•

OFF: Normal

•

ON: Alarm

SYNC

Green

Synchronisation status indication

•

OFF: Not synchronised

•

ON: Synchronised

•

Flashing (60 times per minute): Synchronised (Clock Master)

1

2

Diameter

Maximum Distance

0.5 mm:

Under 200 m

Advertising