4.1 Troubleshooting

232

Installation Manual

System Start-up and On-line Operation

Error Code

Error Message

PROBABLE CAUSE

SOLUTION

000*

MPR WDT overflow

•

MPR card malfunction

•

Optional service card
malfunction: CTI-LINK

•

Erroneous processing of
MPR card software

•

Software error due to
external factors

•

Press the Reset Button

•

Reprogramme the Hybrid IP-PBX

•

Replace the MPR card (be sure to turn
off the Hybrid IP-PBX when replacing)

001

SDRAM bit error

002

System Restart

•

Reset Button is pressed

•

Power failure

•

MPR card malfunction

•

Erroneous processing of
MPR card software

•

Software error due to
external factors

•

Ignore if not frequent

•

Press the Reset Button

•

Reprogramme the Hybrid IP-PBX

•

Replace the MPR card (be sure to turn
off the Hybrid IP-PBX when replacing)

010*

AC power down

•

Power supply system
malfunction (e.g., power
failure, power noise,
trouble with UPS)

•

Bad connection or
breaking of AC cord

•

Power supply circuit (PSU,
back board) malfunction

•

Check the power supply system

•

See if the AC cord is connected
properly

•

Check the AC cord

•

Replace the AC cord (be sure to turn
off the Hybrid IP-PBX when replacing)

•

Replace the PSU (be sure to turn off
the Hybrid IP-PBX when replacing)

•

Replace the back board (be sure to
turn off the Hybrid IP-PBX when
replacing)

011*

DC power down

•

AC power down

•

Power supply circuit (PSU,
back board) malfunction

•

Detection of over current
(short circuit on optional
service cards)

•

Check the power supply system

•

See if the AC cord is connected
properly

•

Check the AC cord

•

Replace the AC cord (be sure to turn
off the Hybrid IP-PBX when replacing)

•

Replace the PSU (be sure to turn off
the Hybrid IP-PBX when replacing)

•

Replace the back board (be sure to
turn off the Hybrid IP-PBX when
replacing)

•

Remove the optional service cards and
restart the Hybrid IP-PBX

012*

MPR RAM battery
low

•

Battery out

•

MPR card malfunction

•

Replace the MPR card (be sure to turn
off the Hybrid IP-PBX when replacing)

014*

FAN Alarm

•

PSU-L malfunction

•

See if anything is jammed in the fan

•

Replace the PSU (be sure to turn off
the Hybrid IP-PBX when replacing)

Advertising