AMETEK Compact IX 2253 User Manual
Page 131
Advertising

User Manual
2253i / 2253iX
AMETEK California
Instruments
131
VOLT SURGE
This test will produce voltage surge defined by Table 9-18. This test will be repeated three times with
ten seconds intervals. The voltage values are halved for 14.0V category B equipment.
Category
Surge 1
Surge 2
Volt
Dwell (msec)
Volt
Dwell (msec)
A 46.3 100 37.8 1000
B 60 100 40 1000
Z 80 100 48 1000
Table 9-18: Abnormal Voltage Surge
9.6.3 Emergency Test
The Emergency test is selected from the DO-160 DC Main Menu. This test will set the output voltage
to 18V for 28V equipment and to 9V for 14V equipment. The test will last for 30 minutes. The
key
(backspace) will terminate the test at any time.