AMETEK Compact i/iX Series Software Manual User Manual

Page 134

Advertising
background image

User Manual

– Rev H

California Instruments

134

Avionics Software

Constant Frequency A350 Power Groups

– iX Series & Compact iX Series.

AC Power Groups

No.

Description

SCF

TCF

SCFH

TCFH

Normal Operation

101

Steady-state voltage and frequency

YES

YES

YES

YES

102

Voltage transients

YES

YES

X

X

103

Voltage modulation

YES

YES

YES

YES

104

Voltage spikes

X

X

X

X

105

Current distortion

YES

YES

YES

YES

106

Voltage distortion 1

P

P

P

P

107

Voltage distortion 2

X

X

X

X

108

Voltage distortion transients

P

P

P

P

109

Inrush current

YES

YES

YES

YES

110

Frequency modulation

YES

YES

YES

YES

111

Voltage DC content

P (2)

P (2)

P (2)

P (2)

112

Voltage modulation due to equipment

YES

YES

YES

YES

113

Voltage spike due to equipment load switching

YES

YES

YES

YES

114

Voltage unbalance transient

N/A

YES

N/A

YES

Abnormal Operation

201

Steady-state voltage and frequency

YES

YES

YES

YES

202

Voltage transients

YES

YES

X

X

203

Voltage modulation

YES

YES

YES

YES

204

Frequency transients

YES

YES

YES

YES

Switching Transients

401

Transparency time

YES

YES

YES

YES

402

Voltage switching transients 1

(1)

(1)

(1)

(1)

403

Voltage switching transients 2

(1)

(1)

(1)

(1)

Power Supply Removal

501

Power line disconnection

YES

YES

YES

YES

Note (1): Provided through ABD Switching Transients test menu.
Note (2): Available on 3001/5001/9003/15003iX only, not Compact iX.

Advertising