AMETEK Compact i/iX Series Software Manual User Manual
Page 134

User Manual
– Rev H
California Instruments
134
Avionics Software
Constant Frequency A350 Power Groups
– iX Series & Compact iX Series.
AC Power Groups
No.
Description
SCF
TCF
SCFH
TCFH
Normal Operation
101
Steady-state voltage and frequency
YES
YES
YES
YES
102
Voltage transients
YES
YES
X
X
103
Voltage modulation
YES
YES
YES
YES
104
Voltage spikes
X
X
X
X
105
Current distortion
YES
YES
YES
YES
106
Voltage distortion 1
P
P
P
P
107
Voltage distortion 2
X
X
X
X
108
Voltage distortion transients
P
P
P
P
109
Inrush current
YES
YES
YES
YES
110
Frequency modulation
YES
YES
YES
YES
111
Voltage DC content
P (2)
P (2)
P (2)
P (2)
112
Voltage modulation due to equipment
YES
YES
YES
YES
113
Voltage spike due to equipment load switching
YES
YES
YES
YES
114
Voltage unbalance transient
N/A
YES
N/A
YES
Abnormal Operation
201
Steady-state voltage and frequency
YES
YES
YES
YES
202
Voltage transients
YES
YES
X
X
203
Voltage modulation
YES
YES
YES
YES
204
Frequency transients
YES
YES
YES
YES
Switching Transients
401
Transparency time
YES
YES
YES
YES
402
Voltage switching transients 1
(1)
(1)
(1)
(1)
403
Voltage switching transients 2
(1)
(1)
(1)
(1)
Power Supply Removal
501
Power line disconnection
YES
YES
YES
YES
Note (1): Provided through ABD Switching Transients test menu.
Note (2): Available on 3001/5001/9003/15003iX only, not Compact iX.