Test No.
Section
Subject
Test Limits
Comment
File Ref.
13.0
Normal DC Steady State
13.1
Normal Steady-State Voltage
+/-120.0 to +/-140.0 Volts
Apply for 30 min each
TYPE6-131
13.2
Common Mode Voltage
1.25 Volts
Apply for 30 min
TYPE6-132
13.3
Differential Mode Voltage - Max Amplitude
2.0 Volts Peak to Peak
Requires Additional Equipment
13.4
Differential Mode Voltage - Max Ripple Components
40kHz - 120kHz
Requires Additional Equipment
14.0
Normal DC Transients
14.1
Voltage Transients
Per Figure 30
TYPE6-141
15.0
Abnormal DC Steady-State
15.1
Steady State Voltage
+/-120.0 to +/-140.0 Volts
Requirement fulfilled in 13.1
16.0
Abnormal DC Transients
16.1
Voltage Transients
Per Figure 31
TYPE6-161