89
4.4.2.7
Type III DC:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
5.0
Normal DC Steady State
5.3
Type 3 DC Voltage
22.0 to 32.8 Volts
TYPE3-53
5.5
Voltage Ripple
5.5.1
Maximum Amplitude
4.0 Volts Peak to Peak
Requirement fulfilled in 5.5.2
5.5.2
Ripple Components
Per Figure 7
Use B787 DC ripple window to perform
6.0
Normal DC Transients
6.1
Voltage Transients
Per Figures 8A through 8E
TYPE3-61
6.2
Voltage Spikes
Per Figure 10
Requires Additional Equipment
7.0
Abnormal DC Steady State
7.3
Type 3 DC Voltage
18.0 to 32.8 Volts
TYPE3-73
8.0
Abnormal DC Transients
8.1
Voltage Transients
Per Figures 9A through 9D
TYPE3-81
SUPP
Supplementary Transient Test Requirements
Tests 1-65, Table 3.3.3-3A
DC3SUPP-1
SUPP
Supplementary Transient Test Requirements
Tests 1-19, Table 3.3.3-3B