AMETEK DLM 600W Series User Manual
Page 69

DLM 600W Series
M362161-01 Rev J
4-11
4.4.4
Resistance Programming of Output Voltage
Refer to Figure 4-6 for setting up resistance programming of the output voltage.
1.
Set Position-8 of the SETUP switch to OFF for 0–5 VDC programming range
2.
Connect the external programming resistance, 0–5 k
, to the REMOTE
ANALOG INTERFACE connector, from Pin-20 to Pin-21.
3.
Connect a jumper from Pin-21 to Pin-9.
7.
Program the other parameters to the desired limit values: CURRENT
PROGRAMMING INPUT, Pin-10, and the OVP PROGRAMMING INPUT, Pin-3,
with respect to Pin-12. AUXILIARY 5VDC OUTPUT, Pin-15, could be used for
full–scale programming.
NOTE: Step 4 is mandatory. The power supply will not work properly without it.
4.
Connect Pin-1, ANALOG–CONTROL, of the REMOTE ANALOG INTERFACE
connector to Pin-6.
Figure 4-6. Resistance Programming of Output Voltage