Resistance Programming of Output Current
Refer to Figure 4-7 for resistance programming of the output current.
1.
Set Position-7 of the SETUP switch to OFF for 0–5 VDC programming range.
2.
Connect the external programming resistance, 0–5 k
, to the REMOTE
ANALOG INTERFACE connector, from Pin-23 to Pin-22.
3.
Connect a jumper from Pin-22 to Pin-10.
8.
Program the other parameters to the desired limit values: VOLTAGE
PROGRAMMING INPUT, Pin-9, and the OVP PROGRAMMING INPUT, Pin-3,
with respect to Pin-12. AUXILIARY 5VDC OUTPUT, Pin-15, could be used for
full–scale programming.
NOTE: Step 4 is mandatory. The power supply will not work properly without it.
4.
Connect Pin-1, ANALOG–CONTROL, of the REMOTE ANALOG INTERFACE
connector to Pin-6.
Figure 4-7. Resistance Programming of Output Current