SECTION 4

ADVANCED OPERATION

4.1 Introduction

The DLM–E Series power supplies offer the following standard features:

•

Remote Programming of Output Voltage and Current Limit with 0–5V, 0–10V or 0–5k
ohms (Section 4.3)

•

Overvoltage Protection (OVP) with front panel control or 0–5, 0–10V or 0–5k ohms
programming (Section 4.4)

•

Programmable Shutdown with DC, or TTL compatible signals and contact closure
(Section 4.5)

•

Fault Signal, TTL compatible, 10 mA source. (Section 4.9)

•

Remote Monitoring of Status Indicators for thermal shutdown, OVP status, remote/local
programming mode, and voltage/current mode operation (Section 4.6)

•

Calibrated Readback Signals for output voltage and output current with selectable 0–5V
or 0–10V scales (Section 4.6)

•

Multiple Supply Configurations such as series, parallel, and split supply (Section 4.7)

•

Remote Voltage Sensing (Section 3.3)

•

Output Voltage Biasing (Section 4.7)

Accessing these features may require that you use one or more of the following procedures:

•

Using the front panel REMOTE/LOCAL programming switch.

•

Reconfiguring the rear panel J3 connector.

•

Making connections to the J3 connector.

•

Resetting rear panel DIP switch S1.