Section 4 advanced operation, 1 introduction, Advanced operation – AMETEK DCS-E 3kW Series User Manual

Page 45

Advertising
background image

M362295-01 Rev C

4-1

SECTION 4

ADVANCED OPERATION

4.1 INTRODUCTION

All DCS-E Series power supplies offer the following standard features:

•

Remote Programming of Output Voltage and Current Limit with 0-5V, 0-10V, 0-1 mA,
and 0-5k ohms (Section 4.3)

•

Overvoltage Protection (OVP) with front panel controls or 0-5V and 0-10V programming
(Section 4.4)

•

Programmable Shutdown with AC, DC, or TTL compatible signals and contact closure
(Section 4.5)

•

Remote Monitoring of Status Indicators for thermal shutdown, OVP status, remote/local
programming mode, and voltage/current mode operation (Section 4.6)

•

Calibrated Readback Signals for output voltage and output current with selectable 0-5V
or 0-10V scales (Section 4.6)

•

Multiple Supply Configurations such as series, parallel, and split supply (Section 4.7)

•

Remote Voltage Sensing (Section 3.3)

•

Output Voltage Biasing (Section 4.8)

Accessing these features may require that you use one or more of the following procedures:

•

Using the front panel REM/LOC (Remote/Local Programming) switch.

•

Reconfiguring the rear panel J3 connector.

•

Making connections to the J3 connector.

•

Resetting internal jumpers JMP1 and JMP2.

•

Resetting internal switch SW1.

Advertising