AMETEK DCS-E 3kW Series User Manual
Page 54

Advanced Operation
Sorensen DCS-E Series 3kW Supplies
4-10
M362295-01 Rev C
Figure 4-5 Programming Output Voltage with a 0-10 Vdc Source
WARNING
Exercise caution when resetting internal jumpers. Review Section 2.2 Safety and
follow procedures for removing the cover and resetting jumpers in Section 4.2.3
Resetting Jumpers and Switch.
P
ROGRAMMING
O
UTPUT
V
OLTAGE WITH A
0-1
M
A S
OURCE
1. Remove the jumper between pins 20 and 21 of connector J3.
2. Connect the external programming source between pin 9 (voltage programming
input/positive) and pin 12 (return) of connector J3.
Varying the current source from 0 to 1 mA will vary the output voltage from 0 to 100% of the
model rating. Adjusting the front panel current limit control sets the output current limit.
Figure 4-6 Programming Output Voltage with a 0-1 mA Source