Advanced Operation
M362295-01 Rev C
4-11
P
ROGRAMMING
O
UTPUT
V
OLTAGE WITH A
0-5
K
R
ESISTANCE
1. Remove the jumpers connecting pins 8 to 9 and pins 20 to 21 on connector J3.
2. Connect pins 9 (voltage programming input/positive) and 21 (1 mA current source for
voltage control) to the counter-clockwise end of the 5k potentiometer and connect the
tap and clockwise end of the potentiometer to pin 12 (return).
Adjusting the resistance from 0 to 5k will vary the output voltage from 0 to 100% of the model
rating. The output current limit is set locally by adjusting the front panel current limit control.
Figure 4-7 Programming Output Voltage with a 5k ohm Resistance